Waterproof 14mm 40khz ultrasonic piezo transducer parking sensor double use sensor
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOutput | Digital Sensor | Measure Distance | 0.2~6m |
---|---|---|---|
Material | Aluminum | Max.input Voltage | 20Vrms |
Frequency | 40khz | USE | Dual Transmitter And Receiver |
Size | 14*10mm | Type | Waterproof Type |
High Light | ultrasonic transducer transmitter,waterproof ultrasonic transducer |
Waterproof 14mm 40khz ultrasonic piezo transducer parking sensor double use sensor
Water proof type ultrasonic sensors were widely used for parking sensors, proximity sensors and level sensors, etc. With perfect seal these sensors can be used in a relatively poor environment such as dust and humidity.
Technical parameters
|
|
Part number
|
TM-1440H10TR |
Construction
|
Water proof type
|
Using method
|
Dual use
|
Center frequency
|
40.0±1.0KHz
|
Sound pressure level
|
105dB min.
|
Sensitivity
|
-82dB min.
|
Capacitance
|
1900Pf±20%
|
Ringing
|
1.2ms max.
|
Maximum input voltage
|
150Vp-p
|
Directivity
|
80°±15° (-6dB)
|
Operating temperature
|
-30°C~+70°C
|
Storage Temperature
|
-40°C~+80°C
|
Specification
Specification Item | Parameter | Remark |
Resonant frequency | 40±1.0kHz | |
Echo Sensitivity | ≥150mV | Simulation test circuit see Figure 1. |
Decay Time | ≤1.05ms | |
Directivity (X) | 120±15° | Directivity test see Fig 2. |
Directivity (Y) | 60±10° | |
Electrostatic Capacitance | 1800±15%pF | 1kHz/25℃ |
Input voltage | ≤140Vp-p | 40kHz/ pulse width 0.5ms/ interval 20ms |
Mean Time to Failure | 50000h | |
Operating temperature | -35~+80℃ | |
Storage temperature | -35~+80℃ |
Dimension
5.1 Sound pressure level and sensitivity shall not change by more than 15dB in temperature range of -20°C to 60°C, at a relative humidity of 30%.
5.2 Sound pressure level and sensitivity shall not change by more than 6dB in the humidity of 10% to 90%, at the temperature of 25°.
5.3 MOISTURE
Keep the sensor at 40°C±2°C and 90°C to 95°C R.H for 96±4 hours. Then, release the sensor into the room conditions for 24 hour prior to the measurement. It shall fulfill the specifications in Table 1.
5.4 VIBRATION
Subject the sensor to the vibration for 1 hour each in the X.Y and Z axes with the amplitude of 1.5mm at 10 to 55 Hz. It shall fulfill the specifications in Table 1.
5.5 HIGH TEMPERATURE EXPOSURE
Subject the sensor to 80±5°C for 24±1 hours. then, release the sensor into the room conditions
for 1 hour prior to the measurement. It shall meet the specifications in Table 1.
5.6 LOW TEMPERATURE EXPOSURE
Subject the sensor to -30±5°C for 24±1 hours. Then release the sensor into the room conditions
for 1 hour prior to the measurement. It shall meet the specifications in Table 1.
Table 1
ITEM
|
SPECIFICATION
|
Center Frequency
|
Within ±0.5KHz
|
Echo Voltage
|
Within ±20mv
|
Ringing
|
Within ±0.2ms
|
NOTES
This sensor is designed for use in air. Do not use this sensor in fluid.
In case where this sensor is to be hold in housing, use soft buffer between sensor and housing. The front part of this sensor vibrates in large.
If this part is hold, its characteristics will vary. The top must be free to vibrate.
To prevent sensor malfunctions, operational failure or any deterioration of its characteristics, do not use this sensor in the following, or similar conditions.
A. In strong shock or vibration.
B. In high temperature and humidity for a long time.
C. In corrosive gases or sea breeze.
D. In an atmosphere of organic solvents.
E. In dirty and dusty environments that may contaminate the sensor front.